Skip to content

Home | Display | Remote control

Remote Control Interfaces (CMDNET)

Immersive Display PRO can be operated headlessly and integrated with external show control platforms, AV automation controllers (Crestron, AMX, Extron), or custom simulation master consoles.


CMDNET TCP Interface

CMDNET is an ASCII text-based TCP socket protocol. The server processes incoming commands sequentially and issues a single matching response for each request.

  • Default Port: Configurable in Settings > Network (default: 6600).
  • Command Syntax: <COMMAND> <PARAMETER>; (commands end with a semicolon).
  • Response Syntax: <RESULT_CODE>:<RESULT_INFO>; (returns OK or ERR).

Command Reference

Command Parameter Example Response Example Description
HELP; None OK:HELP,GETDESKTOPWARPING...; Lists all supported CMDNET commands.
GETDESKTOPWARPING; None OK:ENABLED; or OK:DISABLED; Returns desktop warping state.
SETDESKTOPWARPING ENABLE; or DISABLE; OK:ENABLED; Enables or disables desktop warping.
GETWINDOWWARPING; None OK:ENABLED; Returns window/game warping state.
SETWINDOWWARPING ENABLE; or DISABLE; OK:ENABLED; Enables or disables 3D application warping.
SETCONFIGSET 1; to 8; OK:2; Switches active configuration set.
SETBLACKOUT ENABLE; or DISABLE; OK:ENABLED; Blanks out all warped projector outputs to black.
SETPOSE 1; to 8; OK:2; Activates a predefined 6-DOF simulator head pose.
LOADPROCALIB "\\.\DISPLAY1" "C:\calib.procalib"; OK:LOADED; Loads a calibration file into a display.
SHOW; None OK:SHOW; Restores the configuration GUI.
HIDE; None OK:HIDE; Minimizes the GUI to the system tray.
QUIT; None OK:QUIT; Shuts down Immersive Display PRO.